{"id":15993,"date":"2024-02-05T15:15:21","date_gmt":"2024-02-05T14:15:21","guid":{"rendered":"http:\/\/eqgkrdm.cluster031.hosting.ovh.net\/?p=15993"},"modified":"2024-03-01T14:53:47","modified_gmt":"2024-03-01T13:53:47","slug":"organ-on-chip-a-general-overview","status":"publish","type":"post","link":"https:\/\/blog.darwin-microfluidics.com\/organ-on-chip-a-general-overview\/","title":{"rendered":"Organ-On-Chip: a general overview"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"15993\" class=\"elementor elementor-15993\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-57e41a8b elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"57e41a8b\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-623ddb2c\" data-id=\"623ddb2c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7ed8cbf1 elementor-widget elementor-widget-text-editor\" data-id=\"7ed8cbf1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><\/p>\n<h2 class=\"wp-block-heading\">What are organ-on-chips?<\/h2>\n<p><\/p>\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/darwin-microfluidics.com\/collections\/microfluidic-organ-on-a-chip\"><strong><span style=\"color: #0000ff;\">Organ-on-chips<\/span><\/strong><\/a> (OoC) or <strong>Micro-Physiological Systems<\/strong> (MPS) are microfluidic systems that allow the growth of cells to model biological tissues. These platforms combine a multicellular environment with a 2D or 3D structure and mechanical cues to mimic the physiological environment of an organ.<\/p>\n<p><\/p>\n<h2 class=\"wp-block-heading\">Why is 3D important in cell-culture?<\/h2>\n<p><\/p>\n<p class=\"wp-block-paragraph\">Currently, <em><strong>in vitro<\/strong><\/em> testing occurs mainly on a single cell type, cultured in 2D, in hard, flat, polystyrene flasks or plates. Even if those techniques have been useful in deciphering some phenomena, it is clear that they do not reproduce the environment of cells inside a body. In the human body, organs are made of multiple cell types, arranged in a 3D structure, and surrounded by extracellular matrix and other tissues that are usually a lot softer than plastics. In 2D monolayers, <strong>cell morphology<\/strong>, and polarity are forced and not representative of reality. In addition, the constraints in terms of nutrient access and spreading or migration are non-existent in 2D and again do not model what happens inside the body. <strong>Cellular interactions<\/strong> with the environment or with other cell types are also lacking in 2D models.<\/p>\n<p><\/p>\n<h2 class=\"wp-block-heading\">Why are mechanical cues important in cell development?<\/h2>\n<p><\/p>\n<p class=\"wp-block-paragraph\">As exposed above, in the body, tissues are exposed to different types of mechanical forces from their environment. Some organs like muscles are subjected to <strong>compression and stretch<\/strong> cycles that contribute to cell development and fate. Without those mechanical forces, the cell would behave differently, thus it is important to reproduce those forces in a 3D <strong>in vitro<\/strong> model to better mimic pathologies and also take this natural motion into account for therapy development. Not only should one take into account the nature of the biomechanics stimulation but also its amplitude, frequency, and duration.<\/p>\n<p><\/p>\n<p class=\"wp-block-paragraph\"><strong>Blood circulation<\/strong> is another component of the biomechanics in the body. The <strong><a href=\"https:\/\/darwin-microfluidics.com\/blogs\/reviews\/shear-stress-in-microfluidic-devices\"><span style=\"color: #0000ff;\">shear stress<\/span><\/a><\/strong> induced by the flow inside capillaries, vessels, and arteries has a profound impact on endothelial cells and overall tissue remodeling. Thus, it is crucial to reproduce a type of blood flow within those new models for mechanical reasons but also biological reasons. Indeed, blood carries nutrients to tissues and cells, and having a dynamic flow allows for a constant supply of fresh nutrients as opposed to a static culture where the same media can stay for several days. Similarly, cellular metabolic waste will be continuously removed and will not accumulate in the cell culture, which could induce toxicity in the cells.<\/p>\n<p><\/p>\n<p><!-- \/wp:list --><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7d48580 elementor-widget elementor-widget-image\" data-id=\"7d48580\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"480\" height=\"414\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Diagram_of_a_Mechanical_Stimulation-A_Crucial_Element_of_Organ-on-Chip_Models_1_480x480.webp\" class=\"attachment-large size-large wp-image-19559\" alt=\"Diagram of a Mechanical Stimulation A Crucial Element of Organ-on-Chip Models\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Diagram_of_a_Mechanical_Stimulation-A_Crucial_Element_of_Organ-on-Chip_Models_1_480x480.webp 480w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Diagram_of_a_Mechanical_Stimulation-A_Crucial_Element_of_Organ-on-Chip_Models_1_480x480-300x259.webp 300w\" sizes=\"(max-width: 480px) 100vw, 480px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-71724f6 elementor-widget elementor-widget-text-editor\" data-id=\"71724f6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"color: #252525; letter-spacing: -0.16px;\"><em>Thompson CL, Fu S, Heywood HK, Knight MM and Thorpe SD (2020) Mechanical Stimulation: A Crucial Element of Organ-on-Chip Models.&nbsp;Front. Bioeng. Biotechnol.&nbsp;8:602646. doi: 10.3389\/fbioe.2020.602646<\/em><\/p>\n<h2 class=\"wp-block-heading\" style=\"font-family: Lato, sans-serif; letter-spacing: -0.16px;\">Why are organ-on-chip developed?<\/h2>\n<p style=\"color: #252525; letter-spacing: -0.16px;\">The need for those tools in research emerged in the drug discovery process to address several unmet expectations.<\/p>\n<ul style=\"letter-spacing: -0.16px;\">\n<li><span style=\"font-weight: bolder;\">Decrease costs and duration<\/span>: currently it can take up to 20 years and billions of dollars to get a drug on the market<\/li>\n<li><span style=\"font-weight: bolder;\">Minimizing animal experimentation<\/span>: pre-clinal testing of toxicity and efficacy of drug candidates is performed on animals such as rodents and primates. Each year, millions of animals are used to model human biology which poses both ethics and scientific relevance considerations.<\/li>\n<li><span style=\"font-weight: bolder;\">Get more relevant models of human biology:<\/span>&nbsp;there is a need for a systemic human model to test toxicity and efficacy in more physiological conditions than current human&nbsp;<em><span style=\"font-weight: bolder;\">in vitro<\/span><\/em>&nbsp;or animal&nbsp;<span style=\"font-weight: bolder;\">in vivo<\/span>&nbsp;models.<\/li>\n<\/ul>\n<p style=\"color: #252525; letter-spacing: -0.16px;\">There is high hope that the development and use of new 3D human models might help increase the success rate of drug testing while reducing the costs and duration of drug development.<\/p>\n<h2 class=\"wp-block-heading\" style=\"font-family: Lato, sans-serif; letter-spacing: -0.16px;\">Which applications can organ-on-chip&nbsp;be used for?<\/h2>\n<p style=\"color: #252525; letter-spacing: -0.16px;\">Organ-on-chip can be used for a variety of applications all along the&nbsp;<span style=\"font-weight: bolder;\">drug development<\/span>&nbsp;process, including the critical study of the&nbsp;<a style=\"font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight );\" href=\"https:\/\/darwin-microfluidics.com\/blogs\/reviews\/organ-on-chip-for-blood-brain-barrier-research\"><span style=\"font-weight: bolder;\">blood-brain barrier<\/span><\/a>. They can be used to model diseases to decipher some mechanisms, but also to test drug candidates&rsquo; safety and metabolism. An ultimate goal of organ-on-chip development would be to use them for&nbsp;<span style=\"font-weight: bolder;\">personalized medicine<\/span>, using the patient&rsquo;s specific cells on which one could try several molecules to choose the most effective treatment for the patient. Overall, for optimal use and adhesion of researchers to organ-on-chip, models should be developed to be associated with classic research techniques such as high-resolution imaging, RNA and protein expression, or cell-secreted biomarkers measurement.<\/p>\n<h2 class=\"wp-block-heading\" style=\"font-family: Lato, sans-serif; letter-spacing: -0.16px;\">References:<\/h2>\n<ul style=\"letter-spacing: -0.16px;\">\n<li><span style=\"color: #0000ff;\"><span style=\"font-weight: bolder;\"><a style=\"color: #0000ff; font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight );\" href=\"https:\/\/www.upmbiomedicals.com\/resource-center\/learning-center\/what-is-3d-cell-culture\/2d-versus-3d-cell-culture\/\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.upmbiomedicals.com\/resource-center\/learning-center\/what-is-3d-cell-culture\/2d-versus-3d-cell-culture\/<\/a><\/span><\/span><\/li>\n<li><em>Franzen N, van Harten WH, Ret&egrave;l VP, Loskill P, van den Eijnden-van Raaij J, IJzerman M. Impact of organ-on-a-chip technology on pharmaceutical R&amp;D costs. Drug Discov Today. 2019 Sep;24(9):1720-1724. doi: 10.1016\/j.drudis.2019.06.003. Epub 2019 Jun 8. PMID: 31185290.<\/em><\/li>\n<li><em>Thompson CL, Fu S, Heywood HK, Knight MM and Thorpe SD (2020) Mechanical Stimulation: A Crucial Element of Organ-on-Chip Models.&nbsp;Front. Bioeng. Biotechnol.&nbsp;8:602646. doi: 10.3389\/fbioe.2020.602646<\/em><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d051ae8 elementor-widget elementor-widget-global elementor-global-18295 elementor-widget-pix-promo-box\" data-id=\"d051ae8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/17424049-optimized-DDI-Chip_blue2_2048x2048.webp\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"ORGAN-ON-CHIP: THE FUTURE OF RESEARCH?\"\/><a href=\"https:\/\/darwin-microfluidics.com\/collections\/microfluidic-organ-on-a-chip\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Discover our selection!<\/span><\/span><\/span><\/div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">ORGAN-ON-CHIP: THE FUTURE OF RESEARCH?<\/h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Explore our cutting-edge solutions for advanced research and development!<\/span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"><\/i><\/span><\/div><\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>What are organ-on-chips? Organ-on-chips (OoC) or Micro-Physiological Systems (MPS) are microfluidic systems that allow the growth of cells to model biological tissues. These platforms combine a multicellular environment with a 2D or 3D structure and mechanical cues to mimic the&hellip;<\/p>\n","protected":false},"author":3,"featured_media":14848,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_kc_parent_guide":"","_kc_products":"","_kc_type":"","_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[27,21],"tags":[],"class_list":["post-15993","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cell-culture-organ-on-chip","category-overviews"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Organ-On-Chip: a general overview - Darwin Microfluidics<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.darwin-microfluidics.com\/organ-on-chip-a-general-overview\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Organ-On-Chip: a general overview - Darwin Microfluidics\" \/>\n<meta property=\"og:description\" content=\"What are organ-on-chips? Organ-on-chips (OoC) or Micro-Physiological Systems (MPS) are microfluidic systems that allow the growth of cells to model biological tissues. These platforms combine a multicellular environment with a 2D or 3D structure and mechanical cues to mimic the...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.darwin-microfluidics.com\/organ-on-chip-a-general-overview\/\" \/>\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\" \/>\n<meta property=\"article:published_time\" content=\"2024-02-05T14:15:21+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-03-01T13:53:47+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/DDI-Chip_blue2_2048x2048-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"997\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Colin Marquet\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/organ-on-chip-a-general-overview\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/organ-on-chip-a-general-overview\\\/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"Organ-On-Chip: a general overview\",\"datePublished\":\"2024-02-05T14:15:21+00:00\",\"dateModified\":\"2024-03-01T13:53:47+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/organ-on-chip-a-general-overview\\\/\"},\"wordCount\":792,\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/organ-on-chip-a-general-overview\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/DDI-Chip_blue2_2048x2048-1.webp\",\"articleSection\":[\"Cell culture &amp; organ-on-chip\",\"Overviews\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/organ-on-chip-a-general-overview\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/organ-on-chip-a-general-overview\\\/\",\"name\":\"Organ-On-Chip: a general overview - Darwin Microfluidics\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/organ-on-chip-a-general-overview\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/organ-on-chip-a-general-overview\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/DDI-Chip_blue2_2048x2048-1.webp\",\"datePublished\":\"2024-02-05T14:15:21+00:00\",\"dateModified\":\"2024-03-01T13:53:47+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/organ-on-chip-a-general-overview\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/organ-on-chip-a-general-overview\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/organ-on-chip-a-general-overview\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/DDI-Chip_blue2_2048x2048-1.webp\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/DDI-Chip_blue2_2048x2048-1.webp\",\"width\":1000,\"height\":997,\"caption\":\"Image of a PDMS chip held by a blue gloved hand\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/organ-on-chip-a-general-overview\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Organ-On-Chip: a general overview\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"name\":\"Blog\",\"description\":\"Our Blog\",\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/darwin-microfluidics\\\/\",\"https:\\\/\\\/darwin-microfluidics.com\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/author\\\/colinmarquet\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Organ-On-Chip: a general overview - Darwin Microfluidics","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.darwin-microfluidics.com\/organ-on-chip-a-general-overview\/","og_locale":"en_US","og_type":"article","og_title":"Organ-On-Chip: a general overview - Darwin Microfluidics","og_description":"What are organ-on-chips? Organ-on-chips (OoC) or Micro-Physiological Systems (MPS) are microfluidic systems that allow the growth of cells to model biological tissues. These platforms combine a multicellular environment with a 2D or 3D structure and mechanical cues to mimic the...","og_url":"https:\/\/blog.darwin-microfluidics.com\/organ-on-chip-a-general-overview\/","og_site_name":"Darwin Microfluidics","article_published_time":"2024-02-05T14:15:21+00:00","article_modified_time":"2024-03-01T13:53:47+00:00","og_image":[{"width":1000,"height":997,"url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/DDI-Chip_blue2_2048x2048-1.webp","type":"image\/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.darwin-microfluidics.com\/organ-on-chip-a-general-overview\/#article","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/organ-on-chip-a-general-overview\/"},"author":{"name":"Colin Marquet","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677"},"headline":"Organ-On-Chip: a general overview","datePublished":"2024-02-05T14:15:21+00:00","dateModified":"2024-03-01T13:53:47+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/organ-on-chip-a-general-overview\/"},"wordCount":792,"publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/organ-on-chip-a-general-overview\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/DDI-Chip_blue2_2048x2048-1.webp","articleSection":["Cell culture &amp; organ-on-chip","Overviews"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog.darwin-microfluidics.com\/organ-on-chip-a-general-overview\/","url":"https:\/\/blog.darwin-microfluidics.com\/organ-on-chip-a-general-overview\/","name":"Organ-On-Chip: a general overview - Darwin Microfluidics","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/organ-on-chip-a-general-overview\/#primaryimage"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/organ-on-chip-a-general-overview\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/DDI-Chip_blue2_2048x2048-1.webp","datePublished":"2024-02-05T14:15:21+00:00","dateModified":"2024-03-01T13:53:47+00:00","breadcrumb":{"@id":"https:\/\/blog.darwin-microfluidics.com\/organ-on-chip-a-general-overview\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.darwin-microfluidics.com\/organ-on-chip-a-general-overview\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/organ-on-chip-a-general-overview\/#primaryimage","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/DDI-Chip_blue2_2048x2048-1.webp","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/DDI-Chip_blue2_2048x2048-1.webp","width":1000,"height":997,"caption":"Image of a PDMS chip held by a blue gloved hand"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.darwin-microfluidics.com\/organ-on-chip-a-general-overview\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.darwin-microfluidics.com\/"},{"@type":"ListItem","position":2,"name":"Organ-On-Chip: a general overview"}]},{"@type":"WebSite","@id":"https:\/\/blog.darwin-microfluidics.com\/#website","url":"https:\/\/blog.darwin-microfluidics.com\/","name":"Blog","description":"Our Blog","publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.darwin-microfluidics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/blog.darwin-microfluidics.com\/#organization","name":"Darwin Microfluidics","url":"https:\/\/blog.darwin-microfluidics.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/darwin-microfluidics\/","https:\/\/darwin-microfluidics.com"]},{"@type":"Person","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https:\/\/blog.darwin-microfluidics.com\/author\/colinmarquet\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/DDI-Chip_blue2_2048x2048-1.webp","_links":{"self":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/15993","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/comments?post=15993"}],"version-history":[{"count":13,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/15993\/revisions"}],"predecessor-version":[{"id":19569,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/15993\/revisions\/19569"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media\/14848"}],"wp:attachment":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media?parent=15993"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/categories?post=15993"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/tags?post=15993"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}