{"id":14087,"date":"2023-02-16T15:54:57","date_gmt":"2023-02-16T14:54:57","guid":{"rendered":"http:\/\/eqgkrdm.cluster031.hosting.ovh.net\/?p=14087"},"modified":"2026-11-19T15:12:14","modified_gmt":"2026-11-19T14:12:14","slug":"step-by-step-guide-to-make-your-pdms-microfluidic-chip","status":"publish","type":"post","link":"https:\/\/blog.darwin-microfluidics.com\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\/","title":{"rendered":"How to Fabricate a PDMS Microfluidic Chip: Step-by-Step Guide"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"14087\" class=\"elementor elementor-14087\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-09bd50b elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"09bd50b\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-75f15f9\" data-id=\"75f15f9\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0b27619 elementor-widget elementor-widget-text-editor\" data-id=\"0b27619\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In this tutorial, we detail all the steps involved in the manufacture of a microfluidic device, through the example of a double emulsion and trapping chip. This protocol, inspired and extracted from the articles written by Ho, Lee and Liu published in 2016 in Scientific Reports and by Kole et al. published in 2015 in J. Res. Natl. Inst. Stand. Technologie, will give you the keys, from design to microfabrication, to build your own device.<\/p><h2>Designing a device<\/h2><p>The design presented below has been designed to generate double emulsion droplets.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b1f709e elementor-widget elementor-widget-image\" data-id=\"b1f709e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"480\" height=\"159\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Design_of_double_emulsion_droplet_device_480x480.webp\" class=\"attachment-large size-large wp-image-14089\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Design_of_double_emulsion_droplet_device_480x480.webp 480w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Design_of_double_emulsion_droplet_device_480x480-300x99.webp 300w\" sizes=\"(max-width: 480px) 100vw, 480px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">The device has two PDMS layers that consist of a deformable microfluidic channel and two independent control valve sets. The control valve set 1 (in purple) facilitates the trapping of droplets inside the trapping chambers and the control valve set 2 (in orange) provides in-plane compression of the trapped droplets. The microfluidic channel is beneath the control layer and is separated by a thin, deformable PDMS membrane. Extracted from Ho, Lee and Liu 2016 Scientific Reports.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f079bb0 elementor-widget elementor-widget-text-editor\" data-id=\"f079bb0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>You can find below a detailed protocol (extracted from Kole et al. published in 2015 in J. Res. Natl. Inst) which will allow you to design a microfluidic device:<\/p><p>1. First of all, it is necessary to use a computer-aided design (CAD) software to design the microfluidic device.<\/p><p>2. Next, we advise you to use the outline of a 100 mm diameter wafer (this obviously depends on the dimensions of your device) and a standard flat as the outer extent of the array device , and pattern device features within center about 90 mm of the wafer to avoid possible edge defects.<\/p><p>3.To manufacture a device with several lithography levels, requiring the application of photoresist to the patterned elements and alignment between subsequent lithography levels, we recommend the following indications :<\/p><p>3.1. You can place the device features, such as the lower alignment marks of the substrate on the first design level. This order is optimal for structuring elements with vertical nanometre dimensions in a flat photoresist film, applied conformally to an unstructured substrate.<\/p><p>If the vertical dimensions of the structured elements in the subsequent <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/photolithography-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">photolithography<\/a> levels are critical, and if the device and array design permits, place the elements on lower levels towards the periphery of the array. This placement will then reduce the variation in the thickness of the centrifugally coated photoresist film on these lower level elements at locations closer to the centre of the wafer where higher level elements will then be placed.<\/p><p>3.2 Next, the lower alignment marks should be placed towards the periphery of the wafer to improve angular alignment and reduce the resulting radial variation in film thickness, and at locations that do not interfere with the characteristics of the device. Ideal placement of the lower alignment marks allows the use of a single strip of linear tape to mask multiple lower alignment marks during centrifugal coating of the photoresist without covering device features. This maintains the visibility of the lower alignment marks while achieving higher levels of <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/photolithography-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">photolithography<\/a>. It is recommended to include at least one pair of lower alignment marks for each higher <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/photolithography-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">photolithography<\/a> level.<\/p><p>3.3. In this third step, you can place device features such as microfluidic channels, inlet and outlet reservoirs, and upper photomask alignment marks on the upper design levels. If the vertical dimensions of these elements are critical, and if the device and die design allows it, then you can place these top level elements closer to the centre of the wafer. This placement will benefit from the reduced variation in film thickness due to the application of a centrifugal photoresist to the lower level elements which are optimally placed towards the periphery of the die. Thus, the lower alignment marks on the substrate should be visible through the upper alignment marks on the photomask, which will mostly be opaque for modelling a mould structure in a negative tone photoresist.<\/p><p>4. Finally, during the <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/photolithography-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">photolithography<\/a> process, you can align the complementary alignment marks through the photomask onto the substrate.<\/p><h2>Patterning a device mold<\/h2><p>It exist many possible approaches to making a mold for a microfluidic device, using different materials and methods. The most widely used is a photolithographic approach that is ideally suited to rapid prototyping. It consists of centrifugally coating and modelling the SU-8, an epoxy-based negative photoresist, on a silicon wafer. Silicon mold for the top substrate was made by double-layer SU-8 patterning, in which the first patterned layer defines the cross-section of the micropipettes, trapping structures and micro fluidic channel while the second layer defines the trapping structures and main micro fluidic channel. Silicon mold for the bottom substrate was made by single-layer SU-8 patterning, which defines trapping structures and main micro fluidic channel.<\/p><h3>Silicon mold for the top substrate<\/h3><p>1. The first step consists of a spin-coating of a nanometric film of SU-8 2010 onto a bare silicon wafer.<\/p><p>1.1. To do this, center the silicon wafer on the chuck of a centrifuge with the help of a centering jig.<\/p><p>1.2 Place about 10 ml of SU-8 2010 in the centre of the wafer, taking care not to create air bubbles.<\/p><p>1.3. The first layer of the top substrate, SU-8 2010 is spin coated on silicon wafer at 5000rpm, which gave a thickness of 8 &micro;m.<\/p><p>2.Heat the silicon wafer with a nanometer film of SU-8 2010 at 95&deg; C for 2 min on a hot plate.<\/p><p>3.The first photolithographic exposure of the SU-8 2010 nanometric film must then be carried out.<\/p><p>3.1. To do this, place the silicon wafer with the nanometric film of SU-8 2010 with the first photomask in the contact aligner.<\/p><p>3.2. Place the silicon wafer with the nanometer film of SU-8 2010 and the photomask in soft contact.<\/p><p>3.3. Use an i-line filter to expose the SU-8 2010 nanometric film at a wavelength of 365 nm with a dose of 80 mJ.cm-2.<\/p><p>4.After exposure, re-bake the silicon wafer with the SU-8 2010 nanometric film on a hot plate at 95 &deg;C for 2 minutes.<\/p><p>5.The pattern can now be developed in the exposed nanometer film of SU-8 2010.<\/p><p>5.1. To do this, immerse the silicon wafer with the exposed nanometer film of SU-8 2010 in the SU-8 developer for 1 minute with gentle stirring.<\/p><p>5.2. Then, rinse the silicon wafer with developed features in SU-8 2010 in isopropyl alcohol for 10 s and blow-dry with nitrogen.<\/p><p>6. Bake the silicon wafer with developed features in SU-8 2010 on a hot plate at 150 &deg;C for 30 min. These patterns adhere firmly to the substrate<\/p><p>7. Mask the areas of the silicon wafer with lower alignment marks patterned in the SU-8 2010 using a strip of masking tape with a width of 6 mm (0.25 in) for example. This masking tape will cover the lower alignment marks during the centrifugal coating process. Do not cover areas of the silicon wafer where higher level device features will be patterned as this will prevent <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/photolithography-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">photolithography<\/a> in these areas.<\/p><p>8. It is now possible to spin-coat the second film of SU-8 2010 on the masked silicon wafer with the first patterns of SU-8 2010.<\/p><p>8.1. To do this, center the silicon wafer with SU-8 2010 patterns on the chuck of a centrifuge with the help of a centering jig.<\/p><p>8.2 Place about 10 ml of SU-8 2010 in the centre of the wafer, taking care not to create air bubbles.<\/p><p>8.3 For the second layer, SU-8 2010 is applied with spinning speed of 2000 rpm and gives a total thickness of 15 &micro;m<\/p><p>9. You can now remove the masking tape<\/p><p>10. Bake the wafer with a microscopic film of SU-8 2010 on a hot plate at 95 &deg;C for 8 minutes.<\/p><p>11.Now you can carry out the second photolithographic exposure of the microscopic film of SU-8 2010.<\/p><p>11.1. To do this, place the silicon wafer with the micro-scale film of SU-8 2010 in the contact aligner along with the second photomask for microscale features of the device.<\/p><p>11.2. Align the previously drawn nanometer marks with the microscopic marks on the photomask. Be sure to align the upper and lower alignment marks.<\/p><p>11.3. Place the silicon wafer with the micro-scale film of SU-8 2010 and the photomask into soft contact.<\/p><p>11.4. Use an i-line filter to expose the film of SU-8 2010 at a wavelength of 365 nm with a dose of 160 mJ.cm-2.<\/p><p>12. After exposure, bake the silicon wafer with the exposed microscopic film of SU-8 2010 on the hot plate at 95 &deg;C for 8 minutes.<\/p><p>13. It is now time to develop the pattern in the exposed microscopic film of SU-8 2010.<\/p><p>13.1. To do this, prepare two SU-8 developer containers for a first bulk removal of SU-8 2010, followed by a cleaning rinse.<\/p><p>13.2 Immerse the wafer with the exposed microscopic film of SU-8 2010 in the first container for 45 s with gentle shaking.<\/p><p>13.3 Immerse the wafer with the partially developed microscopic film of SU-8 2010 in the second container with gentle stirring for 30 s.<\/p><p>13.4. Rinse the wafer with a fully developed microscopic film of SU-8 2010 with isopropyl alcohol and dry it with nitrogen.<\/p><p>14. Inspect the resulting device mold by light microscopy. If residues of SU-8 2010 persist, rinse the wafer.<\/p><h3>Silicon mold for the bottom substrate<\/h3><p>For the bottom substrate, a single layer of SU-8 2010 was patterned with thickness of 15 &micro;m under a spinning speed of 1500 rpm.<\/p><p>It is recomended to measure the film thickness of the patterned elements of the SU-8 2010 using, for example, a scanning probe surface profilometer or an atomic force microscope.<\/p><h2>Molding a device<\/h2><p>After the silicon molds were fabricated, they were casted with PDMS (Sylgard-184). The control layer was casted in a mixing ratio of 7:1 (base:curing agent). The flow channel membrane was generated by spin-coating PDMS with a mixing ratio of 20:1 on the flow layer silicon mold. Importantly, the PDMS membrane contacts the bottom of the flow channel at 30, 25 and 20 psi for devices with PDMS spin-coating speeds of 1000, 1200 and 1600 rpm respectively. After the PDMS control substrate was diced and punched holes, both the diced PDMS control substrate and the PDMS flow layer membrane on the silicon mold were placed in an oxygen plasma etcher. The diced PDMS control layer substrate was then carefully aligned and bonded with the PDMS flow layer membrane using a customized alignment platform on an optical microscope. A thin PDMS membrane separates the microfluidic channel and the control layers that serve two different functions and are independently controlled. To direct flow to the trapping chambers, a pneumatically controlled valve set located above the microfluidic channel blocks the flow in the main microfluidic channel when the valve set is actuated. A second control valve set directly above the trapping chambers exerts compression to trapped double emulsion when the valve set is actuated. Since the two control valve sets can be independently controlled, trapping is decoupled from compression. Finally, the PDMS substrate was bonded to this glass slide.<\/p><p>Glass capillary microfluidic device was fabricated by assembling tapered round capillary, square capillary and syringe needles together using 5 minutes epoxy. First, the round glass capillary was pulled using a pipette puller. The tapered capillary was then sanded using 1200 grade sandpaper to obtain a 100 &mu; m opening for the collection tube. The outside surface of a clean 15 &mu;m opening injection tube, pulled and similarly sanded, was treated with trichloro(1H,1H,2H,2H-perfluorooctyl)silane to render the surface <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/hydrophobic-microfluidic-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">hydrophobic<\/a>. Then, the injection tube and collection tube were inserted into a square capillary placed on a glass slide and they were aligned under an optical microscope. Syringe needles were cut and glued to the glass slide using 5 minutes epoxy. Lastly, micro-tubings were connected to the syringe needles.<\/p><h2>Trapping of double emulsions<\/h2>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6f4c325 elementor-widget elementor-widget-image\" data-id=\"6f4c325\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"247\" height=\"300\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Scheme_of_an_artificial_cell_generated_by_a_double_emulsion_droplet-247x300.webp\" class=\"attachment-medium size-medium wp-image-14090\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Scheme_of_an_artificial_cell_generated_by_a_double_emulsion_droplet-247x300.webp 247w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Scheme_of_an_artificial_cell_generated_by_a_double_emulsion_droplet-842x1024.webp 842w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Scheme_of_an_artificial_cell_generated_by_a_double_emulsion_droplet-768x934.webp 768w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Scheme_of_an_artificial_cell_generated_by_a_double_emulsion_droplet-1263x1536.webp 1263w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Scheme_of_an_artificial_cell_generated_by_a_double_emulsion_droplet.webp 1456w\" sizes=\"(max-width: 247px) 100vw, 247px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Lipid bilayer partitions the internal environment of a cell where ions do not cross. Double emulsion can serve as a model of an artificial cell where the oil middle phase can vary in thickness and acts as a semi-permeable barrier for ions to pass through. Extracted from Ho, Lee and Liu 2016 Scientific Reports<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fcb436a elementor-widget elementor-widget-text-editor\" data-id=\"fcb436a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Double emulsions were trapped inside the microfluidic device for the application of mechanical forces. Double emulsions with a diameter between 40 &mu;m and 90 &mu;m were first generated in a glass capillary microfluidic device and then reinjected into the microfluidic device at 10x dilution. To trap double emulsions in the trapping chambers, Control valve set 1 was then pressurized at 10 &ndash; 15 psi to block the main microfluidic channel, which increased the flow resistance in the main microfluidic channel. The flow resistance ratio between the microchannels and the main microfluidic channel will reduce and more fluid streamlines will go through the microchannels.<\/p><p>This greatly increases the trapping efficiency of the double emulsions and it is possible to find all 14 trapping chambers filled up within a minute. A double emulsion will be trapped if the radius of the double emulsion is smaller than the instantaneous critical stream width, which is dictated by the flow resistance ratio between the micropipette and main microfluidic channel.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-1a9cea6 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"1a9cea6\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-8d1b10b\" data-id=\"8d1b10b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ef38ab7 elementor-widget elementor-widget-global elementor-global-18322 elementor-widget-pix-promo-box\" data-id=\"ef38ab7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Microfabrication_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"SEEKING PRECISION AT THE NANOSCALE?\"\/><a href=\"https:\/\/darwin-microfluidics.com\/collections\/microfabrication\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Discover our selection!<\/span><\/span><\/span><\/div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">SEEKING PRECISION AT THE NANOSCALE?<\/h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Explore our microfabrication solutions for precise and scalable manufacturing!<\/span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"><\/i><\/span><\/div><\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>In this tutorial, we detail all the steps involved in the manufacture of a microfluidic device, through the example of a double emulsion and trapping chip. This protocol, inspired and extracted from the articles written by Ho, Lee and Liu&hellip;<\/p>\n","protected":false},"author":3,"featured_media":14848,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_kc_parent_guide":"","_kc_products":"","_kc_type":"","_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[33,25],"tags":[],"class_list":["post-14087","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-guides","category-microfabrication"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How to Fabricate a PDMS Microfluidic Chip: Step-by-Step Guide<\/title>\n<meta name=\"description\" content=\"Step-by-step instructions to create your own PDMS microfluidic chip, from materials to final testing\u2014simple, practical, and effective.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.darwin-microfluidics.com\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Fabricate a PDMS Microfluidic Chip: Step-by-Step Guide\" \/>\n<meta property=\"og:description\" content=\"Step-by-step instructions to create your own PDMS microfluidic chip, from materials to final testing\u2014simple, practical, and effective.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.darwin-microfluidics.com\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\/\" \/>\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\" \/>\n<meta property=\"article:published_time\" content=\"2023-02-16T14:54:57+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:12:14+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/DDI-Chip_blue2_2048x2048-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"997\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Colin Marquet\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"11 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\\\/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"How to Fabricate a PDMS Microfluidic Chip: Step-by-Step Guide\",\"datePublished\":\"2023-02-16T14:54:57+00:00\",\"dateModified\":\"2026-11-19T14:12:14+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\\\/\"},\"wordCount\":2099,\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/DDI-Chip_blue2_2048x2048-1.webp\",\"articleSection\":[\"Guides &amp; tutorials\",\"Microfabrication\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\\\/\",\"name\":\"How to Fabricate a PDMS Microfluidic Chip: Step-by-Step Guide\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/DDI-Chip_blue2_2048x2048-1.webp\",\"datePublished\":\"2023-02-16T14:54:57+00:00\",\"dateModified\":\"2026-11-19T14:12:14+00:00\",\"description\":\"Step-by-step instructions to create your own PDMS microfluidic chip, from materials to final testing\u2014simple, practical, and effective.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/DDI-Chip_blue2_2048x2048-1.webp\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/DDI-Chip_blue2_2048x2048-1.webp\",\"width\":1000,\"height\":997,\"caption\":\"Image of a PDMS chip held by a blue gloved hand\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Fabricate a PDMS Microfluidic Chip: Step-by-Step Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"name\":\"Blog\",\"description\":\"Our Blog\",\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/darwin-microfluidics\\\/\",\"https:\\\/\\\/darwin-microfluidics.com\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/author\\\/colinmarquet\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Fabricate a PDMS Microfluidic Chip: Step-by-Step Guide","description":"Step-by-step instructions to create your own PDMS microfluidic chip, from materials to final testing\u2014simple, practical, and effective.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.darwin-microfluidics.com\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\/","og_locale":"en_US","og_type":"article","og_title":"How to Fabricate a PDMS Microfluidic Chip: Step-by-Step Guide","og_description":"Step-by-step instructions to create your own PDMS microfluidic chip, from materials to final testing\u2014simple, practical, and effective.","og_url":"https:\/\/blog.darwin-microfluidics.com\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-16T14:54:57+00:00","article_modified_time":"2026-11-19T14:12:14+00:00","og_image":[{"width":1000,"height":997,"url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/DDI-Chip_blue2_2048x2048-1.webp","type":"image\/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"11 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.darwin-microfluidics.com\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\/#article","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\/"},"author":{"name":"Colin Marquet","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677"},"headline":"How to Fabricate a PDMS Microfluidic Chip: Step-by-Step Guide","datePublished":"2023-02-16T14:54:57+00:00","dateModified":"2026-11-19T14:12:14+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\/"},"wordCount":2099,"publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/DDI-Chip_blue2_2048x2048-1.webp","articleSection":["Guides &amp; tutorials","Microfabrication"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog.darwin-microfluidics.com\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\/","url":"https:\/\/blog.darwin-microfluidics.com\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\/","name":"How to Fabricate a PDMS Microfluidic Chip: Step-by-Step Guide","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\/#primaryimage"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/DDI-Chip_blue2_2048x2048-1.webp","datePublished":"2023-02-16T14:54:57+00:00","dateModified":"2026-11-19T14:12:14+00:00","description":"Step-by-step instructions to create your own PDMS microfluidic chip, from materials to final testing\u2014simple, practical, and effective.","breadcrumb":{"@id":"https:\/\/blog.darwin-microfluidics.com\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.darwin-microfluidics.com\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\/#primaryimage","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/DDI-Chip_blue2_2048x2048-1.webp","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/DDI-Chip_blue2_2048x2048-1.webp","width":1000,"height":997,"caption":"Image of a PDMS chip held by a blue gloved hand"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.darwin-microfluidics.com\/step-by-step-guide-to-make-your-pdms-microfluidic-chip\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.darwin-microfluidics.com\/"},{"@type":"ListItem","position":2,"name":"How to Fabricate a PDMS Microfluidic Chip: Step-by-Step Guide"}]},{"@type":"WebSite","@id":"https:\/\/blog.darwin-microfluidics.com\/#website","url":"https:\/\/blog.darwin-microfluidics.com\/","name":"Blog","description":"Our Blog","publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.darwin-microfluidics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/blog.darwin-microfluidics.com\/#organization","name":"Darwin Microfluidics","url":"https:\/\/blog.darwin-microfluidics.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/darwin-microfluidics\/","https:\/\/darwin-microfluidics.com"]},{"@type":"Person","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https:\/\/blog.darwin-microfluidics.com\/author\/colinmarquet\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/DDI-Chip_blue2_2048x2048-1.webp","_links":{"self":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/14087","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/comments?post=14087"}],"version-history":[{"count":15,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/14087\/revisions"}],"predecessor-version":[{"id":33653,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/14087\/revisions\/33653"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media\/14848"}],"wp:attachment":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media?parent=14087"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/categories?post=14087"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/tags?post=14087"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}