{"id":28338,"date":"2024-09-12T17:24:41","date_gmt":"2024-09-12T15:24:41","guid":{"rendered":"https:\/\/blog.darwin-microfluidics.com\/?post_type=glossary&#038;p=28338"},"modified":"2024-09-12T17:24:42","modified_gmt":"2024-09-12T15:24:42","slug":"absorption-microfluidics-explained","status":"publish","type":"glossary","link":"https:\/\/blog.darwin-microfluidics.com\/glossary\/absorption-microfluidics-explained\/","title":{"rendered":"Absorption"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Definition of Absorption<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Absorption refers to the process by which one substance integrates into another, typically involving interactions between fluids and solid surfaces or within the fluid itself.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Understanding Absorption in Microfluidics<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">In microfluidics, absorption can influence the behavior and performance of microfluidic systems in various ways. It is a complex phenomenon with both physical and chemical aspects.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Physical Absorption<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Physical absorption, also known as physisorption, is a type of absorption that involves weak, short-range forces known as van der Waals forces. These forces cause fluid molecules to adhere to solid surfaces without undergoing a chemical change.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For instance, when a fluid contacts a microfluidic device&rsquo;s surface, physical absorption can alter the fluid flow and needs to be considered in device design to ensure proper functionality.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Chemical Absorption<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">This occurs when absorbed substances react chemically with the surface or within the fluid, leading to changes in properties such as color, state, or reactivity. Chemical absorption is used to drive specific reactions or visual changes, which can be useful in applications like biosensing where precise detection and manipulation of fluids are required.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Importance of Absorption in Microfluidics<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Absorption plays a critical role in microfluidics due to the small scale of the systems. Even minor absorption effects can significantly impact fluid behavior and device performance. Therefore, understanding these effects is crucial for optimizing microfluidic designs and ensuring accurate results.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Advantages of Absorption<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Absorption can enhance microfluidic systems by concentrating substances, removing impurities, or triggering reactions. In biosensing, for example, optimized absorption can improve sensitivity and selectivity, leading to more effective detection of specific molecules.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Challenges Posed by Absorption<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Uncontrolled absorption can lead to issues such as substance loss, contamination, and altered fluid properties. This is particularly important in long-term applications where absorbed substances may accumulate over time. Additionally, predicting and managing absorption requires careful consideration of material properties and system conditions.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img fetchpriority=\"high\" decoding=\"async\" width=\"956\" height=\"236\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/09\/image.png\" alt=\"Absorption of PDMS microfluidic chips\" class=\"wp-image-28339\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/09\/image.png 956w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/09\/image-300x74.png 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/09\/image-768x190.png 768w\" sizes=\"(max-width: 956px) 100vw, 956px\"\/><figcaption class=\"wp-element-caption\">Absorption Properties of PDMS in Microfluidic Chips: The porous structure of PDMS facilitates the diffusion of small <a class=\"glossaryLink\"  href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/hydrophobic-microfluidic-explained\/\"  data-mobile-support=\"0\"  data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex='0' role='link'>hydrophobic<\/a> molecules, such as biological substances and drugs, into the polymer matrix. Adapted from <a href=\"https:\/\/mps.amegroups.org\/article\/view\/4745\/5531\" target=\"_blank\" rel=\"noreferrer noopener\">Wang et al., Microphysiol Syst;2:6 (2018)<\/a>.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Absorption in Different Microfluidic Materials<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The material of the microfluidic device plays a significant role in the absorption process. Different materials exhibit varying absorption characteristics and ach of these has its own&nbsp;advantages and disadvantages when it comes to absorption.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Glass and Silicon<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Glass and silicon are often used in microfluidics due to their <a href=\"https:\/\/blog.darwin-microfluidics.com\/microfabrication-techniques-for-glass-in-microfluidics-a-review\/\">excellent optical properties<\/a> and compatibility with <a href=\"https:\/\/blog.darwin-microfluidics.com\/the-most-used-microfabrication-techniques-in-microfluidics\/\">standard fabrication techniques<\/a>. However, they generally have low absorption rates for non-polar substances.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Polymers<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Polymers, such as <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/17203151\/\" target=\"_blank\" rel=\"noreferrer noopener\">polydimethylsiloxane (PDMS)<\/a>, are also commonly used in microfluidics. PDMS, in particular, is popular due to its flexibility, biocompatibility, and ease of fabrication.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">However, it also has high levels of absorption for non-polar substances&nbsp;which can be a challenge in microfluidic systems that use non-polar solvents or that need to maintain precise concentrations of substances. This can also be an advantage in systems that aim to concentrate substances or remove unwanted substances from a fluid.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Absorption is a fundamental aspect of microfluidics that influences both design and application. By understanding its various forms and impacts, one can better utilize its benefits and mitigate potential drawbacks.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Definition of Absorption Absorption refers to the process by which one substance integrates into another, typically involving interactions between fluids and solid surfaces or within the fluid itself. Understanding Absorption in Microfluidics In microfluidics, absorption can influence the behavior and&hellip;<\/p>\n","protected":false},"author":3,"featured_media":0,"menu_order":0,"template":"","meta":{"footnotes":""},"glossary-categories":[],"glossary-tags":[],"class_list":["post-28338","glossary","type-glossary","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Absorption - Microfluidics Explained<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/absorption-microfluidics-explained\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Absorption - Microfluidics Explained\" \/>\n<meta property=\"og:description\" content=\"Definition of Absorption Absorption refers to the process by which one substance integrates into another, typically involving interactions between fluids and solid surfaces or within the fluid itself. Understanding Absorption in Microfluidics In microfluidics, absorption can influence the behavior and...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/absorption-microfluidics-explained\/\" \/>\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\" \/>\n<meta property=\"article:modified_time\" content=\"2024-09-12T15:24:42+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/09\/image.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/glossary\\\/absorption-microfluidics-explained\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/glossary\\\/absorption-microfluidics-explained\\\/\",\"name\":\"Absorption - Microfluidics Explained\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/glossary\\\/absorption-microfluidics-explained\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/glossary\\\/absorption-microfluidics-explained\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/09\\\/image.png\",\"datePublished\":\"2024-09-12T15:24:41+00:00\",\"dateModified\":\"2024-09-12T15:24:42+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/glossary\\\/absorption-microfluidics-explained\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/glossary\\\/absorption-microfluidics-explained\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/glossary\\\/absorption-microfluidics-explained\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/09\\\/image.png\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/09\\\/image.png\",\"width\":956,\"height\":236},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/glossary\\\/absorption-microfluidics-explained\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Absorption\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"name\":\"Blog\",\"description\":\"Our Blog\",\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/darwin-microfluidics\\\/\",\"https:\\\/\\\/darwin-microfluidics.com\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Absorption - Microfluidics Explained","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.darwin-microfluidics.com\/glossary\/absorption-microfluidics-explained\/","og_locale":"en_US","og_type":"article","og_title":"Absorption - Microfluidics Explained","og_description":"Definition of Absorption Absorption refers to the process by which one substance integrates into another, typically involving interactions between fluids and solid surfaces or within the fluid itself. Understanding Absorption in Microfluidics In microfluidics, absorption can influence the behavior and...","og_url":"https:\/\/blog.darwin-microfluidics.com\/glossary\/absorption-microfluidics-explained\/","og_site_name":"Darwin Microfluidics","article_modified_time":"2024-09-12T15:24:42+00:00","og_image":[{"url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/09\/image.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/blog.darwin-microfluidics.com\/glossary\/absorption-microfluidics-explained\/","url":"https:\/\/blog.darwin-microfluidics.com\/glossary\/absorption-microfluidics-explained\/","name":"Absorption - Microfluidics Explained","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/glossary\/absorption-microfluidics-explained\/#primaryimage"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/glossary\/absorption-microfluidics-explained\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/09\/image.png","datePublished":"2024-09-12T15:24:41+00:00","dateModified":"2024-09-12T15:24:42+00:00","breadcrumb":{"@id":"https:\/\/blog.darwin-microfluidics.com\/glossary\/absorption-microfluidics-explained\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.darwin-microfluidics.com\/glossary\/absorption-microfluidics-explained\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/glossary\/absorption-microfluidics-explained\/#primaryimage","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/09\/image.png","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/09\/image.png","width":956,"height":236},{"@type":"BreadcrumbList","@id":"https:\/\/blog.darwin-microfluidics.com\/glossary\/absorption-microfluidics-explained\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.darwin-microfluidics.com\/"},{"@type":"ListItem","position":2,"name":"Absorption"}]},{"@type":"WebSite","@id":"https:\/\/blog.darwin-microfluidics.com\/#website","url":"https:\/\/blog.darwin-microfluidics.com\/","name":"Blog","description":"Our Blog","publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.darwin-microfluidics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/blog.darwin-microfluidics.com\/#organization","name":"Darwin Microfluidics","url":"https:\/\/blog.darwin-microfluidics.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/darwin-microfluidics\/","https:\/\/darwin-microfluidics.com"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/glossary\/28338","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/glossary"}],"about":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/types\/glossary"}],"author":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/users\/3"}],"version-history":[{"count":1,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/glossary\/28338\/revisions"}],"predecessor-version":[{"id":28340,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/glossary\/28338\/revisions\/28340"}],"wp:attachment":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media?parent=28338"}],"wp:term":[{"taxonomy":"glossary-categories","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/glossary-categories?post=28338"},{"taxonomy":"glossary-tags","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/glossary-tags?post=28338"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}